Description
QIUSUO Potassium Ion Meter Handheld K Ion Meter with Calibration Fluid Range 0.04 to 39000 ppm Accuracy ±1% F.S. 2 to 5 Points Calibration Measurement Units ppm mg/L mol/L mmol/L USB Communication Interface for Testing Potassium Ion
About this item:
Professional portable potassium ion meter, suitable for outdoor applications, accuracy: 1% F.S.
2 to 5 points calibration from low to high concentrations.
USB communication interface, easy to transfer data or connect the power adapter to the instrument
Expanded memory to store or access up to 500 data sets.
Selectable ion measurement units, including ppm, mg/L and mol/L.
Features:
Professional portable potassium ion meter is equipped with a backlit LCD display.
2 to 5 points calibration from low to high concentrations.
Selectable 8 concentration calibration points, ranging from 0.001 to 10000.
Selectable ion measurement units, including ppm, mg/L and mol/L.
Automatic electrode diagnosis shows the calibration points and slopes.
Automatic temperature compensation ensures accurate readings over the entire range.
Auto-read function senses and locks the measurement endpoint.
Calibration due alarm reminds the user to calibrate the meter regularly.
Auto-power off effectively conserves battery life.
Setup menu allows setting the number of calibration points, ionic valency, stability criteria, temperature unit, date and time, etc.
Reset function automatically resumes all settings back to the factory defaults.
Expanded memory stores or recalls up to 500 data sets.
USB communication interface for data transfer or connecting a power adapter to the meter.
Ion Concentration
Range:0.04 to 39000 ppm
Resolution:0.001, 0.01, 0.1, 1, automatic
Accuracy:±1% F.S.
Calibration:2 to 5 points
Calibration Solutions:0.001 / 0.01 / 0.1 / 1 / 10 / 100 / 1000 / 10000
Measurement Units:ppm, mg/L, mol/L, mmol/L
mV
Range:-1999.9 to 1999.9 mV
Resolution:0.1 mV
Accuracy:±0.2 mV
Temperature
Range:0 to 105°C / 32 to 221°F
Resolution:0.1°C/°F
Accuracy:±0.5°C / ±0.9°F
Calibration:1 point
Calibration Range:Reading ±10°C/°F
Other Specifications
Temperature Compensation:0 to 100°C / 32 to 212°F, manual or automatic
Hold Function:Manual / Auto-read measurement endpoint
Stability Criteria:Low / High
Calibration Due Alarm:1 to 31 days or off
Auto-Power Off:10 / 20 / 30 minutes after last key pressed
Meter includes
ISE-K potassium electrode
TP-10K temperature probe
Potassium standard solutions 100, 1000 ppm
Ionic strength adjuster
Electrode clip
Carrying case