QIUSUO Benchtop Iodide Ion Meter Lab I Ion Meter with Calibration Fluid Range 0.04 to 39000 ppm Accuracy±1% F.S.2 to 5 Points Calibration Automatic Temperature Compensation Function USB Communication Interface for Testing I Ion
About this item:
Professional iodide ion meter, suitable for laboratory applications, measurement range 0.06 to 127000 ppm
2 to 5 points calibration, including the selection of 8 concentration points
Selectable concentration units - ppm, mg/L and mol/L
Automatic electrode diagnosis shows the calibration points and slopes
Automatic temperature compensation ensures accurate readings over the entire range
Features:
Professional iodide ion meter is equipped with a large backlit LCD display.
2 to 5 points calibration, including the selection of 8 concentration points.
Direct ion concentration readout simplifies the measurement process.
Selectable concentration units - ppm, mg/L and mol/L.
Automatic temperature compensation ensures accurate readings over the entire range.
Auto-read function senses and locks the measurement endpoint.
Calibration due alarm reminds user to calibrate the meter regularly.
Automatic electrode diagnosis shows the calibration points and slopes.
Setup menu allows setting the number of calibration points, ionic valency, stability criteria, temperature unit, auto-power off, etc.
Reset function automatically restores all settings to the factory defaults.
Expanded memory stores or recalls up to 500 data sets.
USB communication interface enables easy data transfer and timed interval readings.
Ion Concentration
Range 0.06 to 127000 ppm
Resolution 0.001, 0.01, 0.1, 1, automatic
Accuracy ±1% F.S.
Calibration 2 to 5 points
Calibration Solutions 0.001 / 0.01 / 0.1 / 1 / 10 / 100 / 1000 / 10000
Measurement Units ppm, mg/L, mol/L, mmol/L
mV
Range -1999.9 to 1999.9 mV
Resolution 0.1 mV
Accuracy ±0.2 mV
Temperature
Range 0 to 105°C / 32 to 221°F
Resolution 0.1°C/°F
Accuracy ±0.5°C / ±0.9°F
Calibration 1 point
Calibration Range Reading ±10°C/°F
Other Specifications
Temperature Compensation 0 to 100°C / 32 to 212°F, manual or automatic
Hold Function Manual / Auto-read measurement endpoint
Stability Criteria Low / High
Calibration Due Alarm 1 to 31 days or off
Memory Stores up to 500 data sets
Output USB communication interface
Connector BNC, 3.5 mm jack socket
Display Custom LCD (125 × 100 mm)
Power Supply 5V DC power adapter
Environmental Conditions 0 to 50°C / 32 to 122°F, relative humidity < 80%
Dimensions 210 × 188 × 60 mm
Weight 1.5 kg
Meter Includes
ISE-I iodide electrode
TP-10K temperature probe
Iodide standard solutions 100, 1000 ppm
Ionic strength adjuster
USB cable
5V DC power adapter