{"product_id":"qiusuo-turbidity-meter-turbidity-measurement-instrument-with-range-0-to-20-ntu-minimum-indication-0-01-ntu-formazine-standard-turbidity-solution-for-measuring-tap-water-mineral-water-etc","title":"QIUSUO Turbidity Meter Turbidity Measurement Instrument with Range 0 to 20 NTU Minimum Indication 0.01 NTU Formazine Standard Turbidity Solution for Measuring Tap Water Mineral Water Etc","description":"\u003cp class=\"a-spacing-base\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003e\u003cspan class=\"a-text-bold\"\u003eBattery Not included During The Shipping\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003e\u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003e\u003cspan class=\"a-text-bold\"\u003eFormazine Standard Turbidity Solution is included During The Shipping !!!\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAbout this item:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLCD screen with backlight makes reading more comfortable and unaffected by natural light.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eUnique positioning structure and high-precision optical path system effectively ensure the accuracy and repeatability of measured values.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eUsing low drift, high precision, good stability circuit system and high efficiency and long life light source can effectively ensure the long-term stable operation of the instrument.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe instrument can be powered by AC and DC, with low power consumption configuration, compact and lightweight design, which is convenient for field or laboratory use.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eLow voltage indication function, timely instruct users to replace batteries to ensure accurate and effective measurement values.\u003cstrong\u003e\u003cspan class=\"a-text-bold\"\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"celwidget aplus-module 3p-module-b aplus-standard\" data-csa-c-id=\"kmwv6w-a45kfm-9x5yfx-178vt3\" data-cel-widget=\"aplus-3p-module-b\"\u003e\n\u003cdiv class=\"aplus-module-wrapper aplus-3p-fixed-width\"\u003e\n\u003cp class=\"a-spacing-base\"\u003e\u003cstrong\u003e\u003cspan class=\"a-text-bold\"\u003eGeneral Description:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003ePortable Turbidity Meter is designed for turbidity measurement in accordance with International Turbidity Measurement Standards ISO7027, and provides measurements in traditional unit of NTU, EBC, ASBC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"celwidget aplus-module launchpad-brand-description-left aplus-standard\" data-csa-c-id=\"18znw9-evpai2-w7nmvd-664e5s\" data-cel-widget=\"aplus-launchpad-brand-description-left\"\u003e\n\u003cdiv class=\"a-section launchpad-module launchpad-module-brand-description-left\"\u003e\n\u003cdiv class=\"a-section launchpad-text-left-justify\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"a-text-bold\"\u003eTechnical Parameter:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eMeasuring principle: 90° scattered light\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"a-list-item\"\u003e\u003cspan class=\"a-text-bold\"\u003eMeasurement range: 0-20 NTU\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"a-list-item\"\u003eMinimum indication:\u003cspan class=\"a-text-bold\"\u003e 0.01 NTU\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eZero drift: ±1.5%(F.S 30min)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eIndicative stability: ±1.5%(F.S 30min)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eRepeatability (Linear Error): ≤2%\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eIndicative error (basic error):\u003cspan class=\"a-text-bold\"\u003e\u003cspan\u003e \u003c\/span\u003e±8%\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003ePower supply: No.5 Battery x4 Pcs \/ 6V power adapter\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eNet weight:0.4kg\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eHost size:105*195*95mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eStorage Requirement:Temperature 0-45℃, humidity\u0026lt;85%.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"a-text-bold\"\u003ePacking List\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eTurbidity Meter------------ 1\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eOperating Manual--------- 1\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003ePower Adapter------------- 1\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eExchange Plug------------- 1\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eShade cover---------------- 1\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eSample Cell---------------- 2\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003e\u003cspan class=\"a-text-bold\"\u003eFormazine Standard Turbidity Solution---------------- 1\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"a-text-bold\"\u003eApplications:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eThe instrument widely apply to the turbidity measurement in power plants, waterworks, life sewage treatment plants, drink factories, process water, brewage and drug manufactures departments, hospitals and so on.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eNote: 1 EBC = 4 NTU (EBC European Brewing Industry Turbidity Unit)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003e1 ASBC = 0.058 NTU (ASBC American Brewing Industry Turbidity Unit)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"a-text-bold\"\u003eCharacteristics:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eThe large bright LCD makes the reading more comfortable, effective abvoid natural light influence.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eThe succinct operation, broad measuring range and high cost performance ratio , can suit to various professional applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eThe unique localization structure and high accuracy optical path system effectively the measuring value correctness and repeatability\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003eIn order to avoid affecting the light pass rate, do not touch the optical components in the machine straightly. When maintenance, use absorbent cotton dip in with the mixture of alcohol and aether to clean the surface.\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0928\/4694\/8715\/files\/1_84d1f3b1-1de9-42b5-ab0c-22b67d26c646.jpg?v=1780561419\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0928\/4694\/8715\/files\/2_8b70a87f-e0de-4efe-bd0d-cdd5ddbd4996.jpg?v=1780561422\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0928\/4694\/8715\/files\/3_28567061-d9b9-4f72-a9ea-57d0b3d44e4c.jpg?v=1780561428\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0928\/4694\/8715\/files\/4_f2c5c806-0ca5-4075-b4cc-0c74cb093e17.jpg?v=1780561431\" alt=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"QIUSUO Lab Instruments","offers":[{"title":"Default Title","offer_id":52380656370027,"sku":"SGZ-20B-YUEFENG-VICKY-1","price":281.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0928\/4694\/8715\/files\/0ff52347-4e4f-4774-a60d-5205bac93f9a.jpg?v=1757467575","url":"https:\/\/qiusuolab.com\/products\/qiusuo-turbidity-meter-turbidity-measurement-instrument-with-range-0-to-20-ntu-minimum-indication-0-01-ntu-formazine-standard-turbidity-solution-for-measuring-tap-water-mineral-water-etc","provider":"QIUSUO Lab Instruments","version":"1.0","type":"link"}